IDRAC UI inaccessible after 7.00.00.00 firmware Upgrade
Issue
Post upgrade of the iDRAC firmware to 7.00.00.00 using NetWitness Firmware & BIOS Updates, the iDRAC UI becomes inaccessible.Cause
This issue is due to custom iDRAC SSL certificates.
Resolution
Please use one of the below options to make iDRAC UI accessible.Option1:
- Access racadm by SSHing into the server that contains the inaccessible iDRAC.
- Run the below command to reset custom certificates to default certificates so the UI is accessible again.
#racadm sslresetcfg
sample output
Certificate generated successfully and webserver restarted.”
Option2:
Physically hold the iDRAC reset button on the appliance as documented in https://www.dell.com/support/kbdoc/en-in/000126703/how-to-reset-the-internal-dell-remote-access-controller-idrac-on-a-poweredge-server#SystemIdentificationButton
The IDRAC UI will be accessible now. This issue will be fixed in the next firmware release. Please check our NetWitness Firmware & BIOS Updates for the fixed iDRAC version once released.
Product Details
RSA Product Set: NetWitness PlatformRSA Product/Service Type: RSA NetWitness Platform
RSA Version/Condition: 11.0 and later
Hardware Model: Series 6 R640/R740/R740xd
Summary
This document outlines the procedure to access IDRAC UI.