Issue

The Dell appliance iDRAC shows that there is a Critical Fan issue.
User-added

The iDRAC log shows that there is Fan error FAN00229, "The fan that is identified in the message is either removed, incorrectly installed, or not present".
User-added

The iDRAC hardware report of the fans in the appliance shows the fan that is identified in the message has an incorrect status.
User-added

Cause

The Dell appliance fan may need re-seating to ensure that there is proper electrical contact within the chassis, or it has failed.


Resolution

Confirm that the Customer on-site person has the skills to open the NetWitness appliance and re-seating the fan that is mentioned in the iDRAC message before giving permission to open the chassis.

After opening the NetWitness appliance on the inside the lid is a diagram showing the location of the various internal components.

In the above example the iDRAC message refers to Fan 7A and 7B, the single Fan 7 unit includes both Fan 7A/7B.

The row of fans will have a number identifying each one, find the fan number that is mentioned in the iDRAC message.
User-added

The following YouTube video link shows how to open a Dell appliance and how to pull and re-insert a fan.

Reference: Dell EMC PowerEdge R640: Remove/Install Fan

Remove and fully re-insert the Fan.

After re-seating the Fan, re-assemble the appliance and check if the issue is resolved.

If the issue persists, then proceed to order an RMA replacement appliance.
Reference: Internal: RMA Handling tips

Notes

This Dell document lists many of the other Dell appliance error codes.

Reference: PowerEdge R940 | Event and Error Message Reference Guide for 14th Generation Dell EMC PowerEdge Servers Version 1.90

Product Details

RSA Product Set: NetWitness Platform
RSA Product/Service Type: Core Appliance
RSA Version/Condition: 12.x
Platform: CentOS
O/S Version: 7
Product Name: Dell appliance

Summary

The NetWitness appliance iDRAC show a FAN0029 error message, Fan xx is either removed, incorrectly installed, or not present.