NetWitness Zone Configuration on Western Digital Ultrastar 60 Download
Tags: zoning files, sbin files
The following article contains a summary of the NetWitness® Zone Configuration on Western Digital Ultrastar 60 storage. Each of the zone files referenced below are in the ZIP file attached to this document. To see the ZIP file, go to Attachments on this article and download the associated file.
Summary of NetWitness® Zone Configuration on Western Digital Ultrastar 60
This article summarizes the different zone configurations of the Western Digital Ultrastar 60 storage for NetWitness. All the zone files referenced are in a ZIP file and attached to this document.
Below is the SHA256 hash of the attached file. Always check the hash before applying any download.
H4060-J_5_Hosts_X12_scenario_01.zip: SHA256 HASH (4005120ee0064357c17d999e7999a692923d0afa6c6a99b87782072f8e73a3c0)
Zoning
Each Ultrastar Data 60 can support up to 5 NetWitness appliances connected simultaneously by using the Ultrastar’s zoning feature.
The Ultrastar 60 contains 5 columns of hard drives each containing 12 hard drives for a total of 60 drives per enclosure, these columns can be zoned into their own enclave depending on your specific use case.
Using this feature you can connect multiple appliances to the same enclosure and ensure that only the configured Zones are visible to specific appliances.
Predefined Zones
NetWitness only supports the following 6 predefined zones. These predefined zones definition files are:
Zone Config 0
This is the default zone configuration that all Ultrastar 60 are configured with from the factory. It allows all drives to be viewed from all interfaces on the Ultrastar
Zone Config 0 - 1x
Zone Configuration file: Default zoning. No configuration file required.
Zone Config 1
This config uses a 1x1x1x1x1 configuration and supports 5 NetWitness devices simultaneously. Each device can only access 12 drives.
Zone Config 1 - 1x1x1x1x1
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_01.bin
Zone Config 2
This config uses a 2x1x1x1 configuration and supports 4 NetWitness devices simultaneously
Zone Config 2 - 2x1x1x1
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_02.bin
Zone Config 3
This config uses a 3x1x1 configuration and supports 3 NetWitness devices simultaneously.
Zone Config 3 - 3x1x1
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_03.bin
Zone Config 4
This config uses a 4x1 configuration and supports 2 NetWitness devices simultaneously.
Zone Config 4 - 4x1
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_04.bin
Zone Config 5
This config uses a 2x2x1 configuration and supports 3 NetWitness devices simultaneously.
Zone Config 5 - 2x2x1
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_05.bin
Zone Config 6
This config uses a 3x2 configuration and supports 2 NetWitness devices simultaneously.
Zone Config 6 - 3x2
Zone Configuration file: H4060-J_5_Hosts_X12_scenario_06.bin
References: 12.5.1 Storage Guide: Storage Guide Western Digital Ultrastar Data 60 Storage Installation and Configuration section
The following article contains a summary of the NetWitness® Zone Configuration on Western Digital Ultrastar 60 storage. Each of the zone files referenced below are in the ZIP file attached to this document. To see the ZIP file, go to Attachments on this article and download the associated file.
Attachments:
H4060-J_5_Hosts_X12_scenario_01_06.zip